4p 400A dual power circuit breaker electrical automatic transfer switch for gensets

4P 400A Dual power circuit breaker electrical automatic transfer switch for genset What dual power automatic transfer switch?Dual-power automatic transfer switch is microprocessor, which is used to start and switch between grid power and grid power or between grid power and generator power supply in power grid system.

Featured Products

4P 400A Dual power circuit breaker electrical automatic transfer switch for genset 
What dual power automatic transfer switch?

Dual-power automatic transfer switch is microprocessor, which is used to start and switch between grid power and grid power or between grid power and generator power supply in power grid system. It can supply power continuously. Series of dual power supply, when the common use of sudden failure or power outage, through the dual power automatic transfer switch, automatically put into the standby power supply (under small load standby power supply can also be supplied by generators), so that the equipment can still operate normally. The most common are elevators, fire protection, monitoring, lighting and so on.
When the generator set is used as emergency lighting power supply, the start-up time and power conversion time of the generator should not exceed 15s. Double power automatic switching switch should choose "city power - generator conversion" special type.

Dual-power automatic transfer switch has the functions of short circuit and overload protection, over-voltage, under-voltage, phase-gap automatic conversion and intelligent alarm, automatic conversion parameters can be set freely outside, and intelligent protection of operating motor. When the fire control center gives a control signal to the intelligent controller, two circuit breakers enter the sub-unit. In the gate state, the computer network interface is reserved for the realization of remote control, remote adjustment, remote communication, remote measurement and other four remote functions.
Rated Current(Ith) 80A100A125A160A250A400A630A800A1000A1250A1600A
Rated insulation voltage(Ui)750V1000V
Rated concussion withstand voltage(Uimp)8KV12KV
Rated working voltage(Ue)AC440V
Rated working current(Ie)AC-31A80100125160250400630800100012501600
AC-35A80100125160250400630800100012501600
AC-33A80100125160250400630800100012501600
Rated connection capacity10le
Rated breaking capacity8le
Rated limited short-circuit current(ls)50kA70kA100kA120kA
Rated short-time withstand current(ls)7kA9kA13kA26kA50kA
Transfer I-II or II-I0.45s0.6s1.2s
Control Power voltageDC24V. 48V. 110V.       AC220V
Electrical consumption 
Rated frequencyStart300W325W355W400W440W
Normal55W62W74W90W98W
Weight(kg) 4 pole 7.27.57.58.89.016.51732364043
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset
4p 400A Dual Power Circuit Breaker Electrical Automatic Transfer Switch for Genset

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours